ITRON Electronic Correction Instrument: Some Common Knowledge about Roots Flow Meters

  ITRON Electronic Correction InstrumentThe manufacturer believes that the structure of the Roots flowmeter includes a measuring chamber within the flowmeter's casing, which contains one or two pairs of lobes that can rotate tangentially. A pair of drive gears is coaxially mounted with two search wheels outside the flowmeter casing, which mesh with each other, allowing the two lobes to connect with each other.

  

ITRON Electronic Correction Instrument


The manufacturer of the ITRON Electronic Correction Instrument believes that the application range of the Roots flowmeter is as follows:

1. The Roots flowmeter is an instrument for accurately measuring gas flow. Based on the principle of volumetric measurement, it is used to accurately measure the total amount of gas flowing through a closed pipeline. The basic types of flowmeters include lobe flow sensors and flow integrators (secondary instruments).

2. The manufacturer of the ITRON Electronic Correction Instrument believes that the Roots flowmeter is suitable for measuring non-corrosive gases such as natural gas, city gas, propane, nitrogen, and industrial inert gases.

3. The Roots flowmeter is mainly used for gas commercial settlement in industries such as catering and hotels, gas measurement in distribution networks, gas measurement in gas pressure regulating stations, and gas measurement in industrial and civilian boilers. It can also be used as a standard flow measurement.

  ITRON Electronic Correction InstrumentThe manufacturer believes that there are precautions for the installation and use of the Roots flowmeter.

1. Before use, check whether the installation of the flowmeter meets the requirements of this manual, whether the fluid flow direction is consistent with the direction indicated by the arrow on the flowmeter casing, and whether the wiring is correct;

2. The flow, pressure, and temperature range of the gas should comply with the specifications;

3. The manufacturer of the ITRON Electronic Correction Instrument believes that for newly laid pipelines or flowmeters that are started for the first time, the bypass valve should be opened before starting, and the gas to be measured or other gases should be used to flush out dirt and impurities in the pipeline;

4. The manufacturer of the ITRON Electronic Correction Instrument believes that the start-stop operation requirements for the Roots flowmeter are: open the bypass valve to allow liquid to flow normally through the bypass valve; slowly open the valve upstream of the flowmeter to fill the flowmeter with gas; vent by loosening the vent screw on the upper cover with a wrench, and immediately tighten the vent screw after venting; close the bypass valve and use the downstream valve to adjust the flow until needed. The flowmeter will enter normal operating status; for continuous flowmeters, the stop operation is the opposite of the start operation; for intermittent flowmeters, stopping or restarting only involves operating (adjusting) the downstream valve; during the operation of the lobe flowmeter, there are no complex operational requirements, just monitor normal operation. When the flow rate is less than the required flow rate, pressure loss can be observed on both sides of the filter. If the pressure loss exceeds 0.05 MPa, the filter needs to be opened and the filter screen cleaned.

  ITRON Electronic Correction InstrumentThe manufacturer believes that the installation points of the Roots flowmeter are as follows:

1. Before installation, impurities in the pipeline must be removed to prevent foreign objects from entering, as any impurities can damage the flowmeter.

2. Before installing the Roots flowmeter into the pipeline, check whether the rotor rotates flexibly.

3. After the flowmeter is installed, there should be no installation stress to avoid damaging the flowmeter.

4. The manufacturer of the ITRON Electronic Correction Instrument believes that after installation is complete, the bolt above the synchronous gear needs to be unscrewed, and a small screwdriver should be used to extend it to the gear chuck. Rotate the rotor to check whether it rotates freely. If there is any sticking phenomenon, remove the flowmeter, clear the debris, and reinstall.